Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Text availability

Article attribute

Article type

Publication date

Search Results

12 results

Filters applied: . Clear all
Page 1
Etripamil Nasal Spray for Conversion of Repeated Spontaneous Episodes of Paroxysmal Supraventricular Tachycardia During Long-Term Follow-Up: Results From the NODE-302 Study.
Ip JE, Coutu B, Bennett MT, Pandey AS, Stambler BS, Sager P, Chen M, Shardonofsky S, Plat F, Camm AJ. Ip JE, et al. Among authors: stambler bs. J Am Heart Assoc. 2023 Oct 3;12(19):e028227. doi: 10.1161/JAHA.122.028227. Epub 2023 Sep 27. J Am Heart Assoc. 2023. PMID: 37753718 Free PMC article. Clinical Trial.
Subcutaneous implantable cardioverter-defibrillator electrode fracture: Follow-up, troubleshooting, and evaluation.
Kella DK, Stambler BS. Kella DK, et al. Among authors: stambler bs. J Cardiovasc Electrophysiol. 2021 May;32(5):1452-1457. doi: 10.1111/jce.14994. Epub 2021 Mar 19. J Cardiovasc Electrophysiol. 2021. PMID: 33694226
The subcutaneous-implantable cardioverter-defibrillator (S-ICD) and its electrode were developed to avoid long-term complications of transvenous leads in the vasculature. We report a case of unexpected, inappropriate S-ICD shocks due to oversensing of high-amplitude, nonph …
The subcutaneous-implantable cardioverter-defibrillator (S-ICD) and its electrode were developed to avoid long-term complications of …
Search for the optimal right ventricular pacing site: design and implementation of three randomized multicenter clinical trials.
Kaye G, Stambler BS, Yee R. Kaye G, et al. Among authors: stambler bs. Pacing Clin Electrophysiol. 2009 Apr;32(4):426-33. doi: 10.1111/j.1540-8159.2009.02301.x. Pacing Clin Electrophysiol. 2009. PMID: 19335850 Clinical Trial.
To address this issue, three randomized prospective multicenter clinical trials are in progress comparing the long-term effects of RV apical versus septal pacing on left ventricular (LV) function. ...CONCLUSION: These selective site ventricular pacing trials should provide …
To address this issue, three randomized prospective multicenter clinical trials are in progress comparing the long-term effects of RV …
Serial changes in right ventricular apical pacing lead impedance predict changes in left ventricular ejection fraction and functional class in heart failure patients.
Stambler BS, Ellenbogen KA, Liu Z, Levine P, Porter TR, Zhang X; ROVA Trial Investigators. Stambler BS, et al. Pacing Clin Electrophysiol. 2005 Jan;28 Suppl 1:S50-3. doi: 10.1111/j.1540-8159.2005.00028.x. Pacing Clin Electrophysiol. 2005. PMID: 15683525 Clinical Trial.
This study examined whether changes in right ventricular (RV) pacing impedance correlate with changes in left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) functional class during long-term follow-up in pacemaker recipients with CHF. The study …
This study examined whether changes in right ventricular (RV) pacing impedance correlate with changes in left ventricular ejection fraction …
Long-term outcome of patients after successful radiofrequency ablation for typical atrial flutter.
Gilligan DM, Zakaib JS, Fuller I, Shepard RK, Dan D, Wood MA, Clemo HF, Stambler BS, Ellenbogen KA. Gilligan DM, et al. Among authors: stambler bs. Pacing Clin Electrophysiol. 2003 Jan;26(1 Pt 1):53-8. doi: 10.1046/j.1460-9592.2003.00150.x. Pacing Clin Electrophysiol. 2003. PMID: 12685140
The aim of the study was to determine the long-term freedom from atrial arrhythmias after radiofrequency ablation of atrial flutter and to determine the factors associated with recurrent arrhythmias. Radiofrequency ablation has emerged as the preferred treatment for recurr …
The aim of the study was to determine the long-term freedom from atrial arrhythmias after radiofrequency ablation of atrial flutter a …
Examination of the in vivo cardiac electrophysiological effects of nesiritide (human brain natriuretic peptide) in conscious dogs.
Fenelon G, Protter AA, Stambler BS. Fenelon G, et al. Among authors: stambler bs. J Card Fail. 2002 Oct;8(5):320-5. doi: 10.1054/jcaf.2002.127772. J Card Fail. 2002. PMID: 12411983
Spontaneous or induced arrhythmias were not observed during hBNP infusion. CONCLUSIONS: In conscious, healthy dogs, short-term infusion of recombinant hBNP has no significant effects on atrial or ventricular electrophysiologic parameters....
Spontaneous or induced arrhythmias were not observed during hBNP infusion. CONCLUSIONS: In conscious, healthy dogs, short-term infusi …
Clinical characteristics of patients intolerant to VVIR pacing.
Ellenbogen KA, Stambler BS, Orav EJ, Sgarbossa EB, Tullo NG, Love CA, Wood MA, Goldman L, Lamas GA. Ellenbogen KA, et al. Among authors: stambler bs. Am J Cardiol. 2000 Jul 1;86(1):59-63. doi: 10.1016/s0002-9149(00)00828-6. Am J Cardiol. 2000. PMID: 10867093 Clinical Trial.
The incidence and clinical predictors of the development of intolerance to VVIR pacing have not been extensively studied in prospective long-term randomized trials comparing different pacing modes. The frequency and clinical factors predicting intolerance to ventricular pa …
The incidence and clinical predictors of the development of intolerance to VVIR pacing have not been extensively studied in prospective long …
Efficacy of intravenous ibutilide for rapid termination of atrial fibrillation and atrial flutter: a dose-response study.
Ellenbogen KA, Stambler BS, Wood MA, Sager PT, Wesley RC Jr, Meissner MC, Zoble RG, Wakefield LK, Perry KT, Vanderlugt JT. Ellenbogen KA, et al. Among authors: stambler bs. J Am Coll Cardiol. 1996 Jul;28(1):130-6. doi: 10.1016/0735-1097(96)00121-0. J Am Coll Cardiol. 1996. PMID: 8752805 Free article. Clinical Trial.
OBJECTIVES: Currently available antiarrhythmic drugs have limited efficacy for short-term, rapid termination of atrial fibrillation and atrial flutter. ...
OBJECTIVES: Currently available antiarrhythmic drugs have limited efficacy for short-term, rapid termination of atrial fibrillation a …
Long-term temporal patterns of ventricular tachyarrhythmias.
Wood MA, Simpson PM, Stambler BS, Herre JM, Bernstein RC, Ellenbogen KA. Wood MA, et al. Among authors: stambler bs. Circulation. 1995 May 1;91(9):2371-7. doi: 10.1161/01.cir.91.9.2371. Circulation. 1995. PMID: 7729023 Clinical Trial.
BACKGROUND: Technological limitations have precluded investigation of long-term temporal patterns of ventricular tachyarrhythmia recurrences. Newer implantable cardioverter-defibrillators permit such analyses by accurately recording the time and date of tachycardia detecti …
BACKGROUND: Technological limitations have precluded investigation of long-term temporal patterns of ventricular tachyarrhythmia recu …
Late occurrence of incessant atrial tachycardia following the maze procedure.
Ellenbogen KA, Hawthorne HR, Belz MK, Stambler BS, Cherwek ML, Wood MA. Ellenbogen KA, et al. Among authors: stambler bs. Pacing Clin Electrophysiol. 1995 Feb;18(2):367-9. doi: 10.1111/j.1540-8159.1995.tb02528.x. Pacing Clin Electrophysiol. 1995. PMID: 7731886
Finally, we believe this report should emphasize the importance of careful and long-term follow-up of all patients undergoing the maze procedure. Proper evaluation of the place of this therapy greatly depends on reporting of all short- and long-term complications of …
Finally, we believe this report should emphasize the importance of careful and long-term follow-up of all patients undergoing the maz …
12 results