Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Text availability

Article attribute

Article type

Publication date

Search Results

5 results

Filters applied: . Clear all
Page 1
Characteristics and impacts of community aphasia group facilitation: a systematic scoping review.
Pettigrove K, Lanyon LE, Attard MC, Vuong G, Rose ML. Pettigrove K, et al. Among authors: lanyon le. Disabil Rehabil. 2022 Nov;44(22):6884-6898. doi: 10.1080/09638288.2021.1971307. Epub 2021 Oct 9. Disabil Rehabil. 2022. PMID: 34632891
PURPOSE: Community aphasia groups (CAGs) can provide a range of benefits to people with aphasia and support long-term psychosocial wellbeing. However, the dominant speech-pathologist-led service delivery model is inherently limited in scope. ...
PURPOSE: Community aphasia groups (CAGs) can provide a range of benefits to people with aphasia and support long-term psychosocial we …
The cyclooxygenase-2 selective inhibitor NS-398 does not influence trabecular or cortical bone gain resulting from repeated mechanical loading in female mice.
Sugiyama T, Meakin LB, Galea GL, Lanyon LE, Price JS. Sugiyama T, et al. Among authors: lanyon le. Osteoporos Int. 2013 Jan;24(1):383-8. doi: 10.1007/s00198-012-1922-0. Epub 2012 Feb 14. Osteoporos Int. 2013. PMID: 22349912 Free PMC article.
This study determined, in female mice in vivo, the effect of longer term COX-2 inhibition on adaptive (re)modelling of cortical and trabecular bone in response to repeated loading. ...
This study determined, in female mice in vivo, the effect of longer term COX-2 inhibition on adaptive (re)modelling of cortical and t …
Risedronate does not reduce mechanical loading-related increases in cortical and trabecular bone mass in mice.
Sugiyama T, Meakin LB, Galea GL, Jackson BF, Lanyon LE, Ebetino FH, Russell RG, Price JS. Sugiyama T, et al. Among authors: lanyon le. Bone. 2011 Jul;49(1):133-9. doi: 10.1016/j.bone.2011.03.775. Epub 2011 Apr 9. Bone. 2011. PMID: 21497678 Free PMC article.
In conclusion, the response to mechanical loading in both trabecular and cortical bone in mice is therefore not impaired by short-term treatment with risedronate, even over a 1000-fold dose range. ...
In conclusion, the response to mechanical loading in both trabecular and cortical bone in mice is therefore not impaired by short-term
Using functional loading to influence bone mass and architecture: objectives, mechanisms, and relationship with estrogen of the mechanically adaptive process in bone.
Lanyon LE. Lanyon LE. Bone. 1996 Jan;18(1 Suppl):37S-43S. doi: 10.1016/8756-3282(95)00378-9. Bone. 1996. PMID: 8717546 Review.
Exposure to appropriate load-bearing exercise needs therefore to be repeated, probably at daily or alternate-daily intervals. In short-term experiments in rat bones, estrogen amplifies the osteogenic response to a single period of loading. ...
Exposure to appropriate load-bearing exercise needs therefore to be repeated, probably at daily or alternate-daily intervals. In short-te
Increased 3H-uridine levels in osteocytes following a single short period of dynamic bone loading in vivo.
Pead MJ, Suswillo R, Skerry TM, Vedi S, Lanyon LE. Pead MJ, et al. Among authors: lanyon le. Calcif Tissue Int. 1988 Aug;43(2):92-6. doi: 10.1007/BF02555153. Calcif Tissue Int. 1988. PMID: 3142673
There was no obvious correlation between the longitudinal strain distribution during artificial loading and the distribution of labeled osteocytes throughout the bone cross-section. However, previous long-term experiments using a similar loading preparation had consistentl …
There was no obvious correlation between the longitudinal strain distribution during artificial loading and the distribution of labeled oste …