Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Text availability

Article attribute

Article type

Publication date

Search Results

3 results

Filters applied: . Clear all
Page 1
Post-discharge venous thromboembolism prophylaxis in hospitalized trauma patients: A retrospective comparison of patients receiving versus not receiving post-discharge prophylaxis.
Belcher RM, Kay AB, Fontaine GV, Baldwin M, Bledsoe JR, Collingridge DS, Majercik S. Belcher RM, et al. Among authors: bledsoe jr. Am J Surg. 2024 Feb;228:247-251. doi: 10.1016/j.amjsurg.2023.10.032. Epub 2023 Oct 14. Am J Surg. 2024. PMID: 37863796
PDP prescribed in a presumably higher VTE risk trauma population may mitigate the long-term risk of VTE....
PDP prescribed in a presumably higher VTE risk trauma population may mitigate the long-term risk of VTE....
ED Door-to-Antibiotic Time and Long-term Mortality in Sepsis.
Peltan ID, Brown SM, Bledsoe JR, Sorensen J, Samore MH, Allen TL, Hough CL. Peltan ID, et al. Among authors: bledsoe jr. Chest. 2019 May;155(5):938-946. doi: 10.1016/j.chest.2019.02.008. Epub 2019 Feb 16. Chest. 2019. PMID: 30779916 Free PMC article.
OBJECTIVES: This study investigated the association of door-to-antibiotic time with long-term mortality in ED patients with sepsis. METHODS: This retrospective cohort study included nontrauma adult ED patients with clinical sepsis admitted to four hospitals from 2013 to 20 …
OBJECTIVES: This study investigated the association of door-to-antibiotic time with long-term mortality in ED patients with sepsis. M …
Characterization of implantable microfabricated fluid delivery devices.
Rathnasingham R, Kipke DR, Bledsoe SC Jr, McLaren JD. Rathnasingham R, et al. Among authors: bledsoe sc jr. IEEE Trans Biomed Eng. 2004 Jan;51(1):138-45. doi: 10.1109/TBME.2003.820311. IEEE Trans Biomed Eng. 2004. PMID: 14723503
., independent of fluid properties). Functional devices exhibited long-term linearity and reliability in delivering single phase, Newtonian fluids, in discrete volumes with a resolution of 500 picoliters at less than 0.45 lbf/in2 (30 mbar) pressure drop. ...
., independent of fluid properties). Functional devices exhibited long-term linearity and reliability in delivering single phase, New …